You must set the time in order to use the audit trail function. The time should be set in HHmm format based on a 24-hour clock, where HH = hours and mm = minutes. The time should be set when the lock is first set up. The time is to always be set in the local standard time. Local standard time must be set even though daylight savings time may be in effect. To set time perform the following steps:

Enter 78* (SD)
2-digit Programmer PIN position (00) + 6-digit PIN Code #
2-digit Manager or Supervisor PIN position (01-09) + 6-digit PIN Code#
Time in HHmm format#
Time in HHmm format#

EX:
Time set for 5:29 p.m. EDT (daylight savings) using factory default codes.
73* 00123456# 02020202# 1629# 1629#

EX:
Time set for 5:29 p.m. EST (standard time) using factory default codes.
73* 00123456# 02020202# 1729# 1729#

 

Applicable to:
6126, 6127 Audit Lock

 